# UlVac 100 Notes and Rebuild Parts List
#publish
>Navigation: [[Ulvac G-100 Series Rotary Vacuum Pump]], [[Vacuum Technology MOC]]
## Video
https://www.youtube.com/watch?v=OZWPvSt_S7g
## Shaft seals
see [[shaft seals]] for more info
**TC-17-40-9**
## Tips
- With a blank/plug installed on inlet, run the pump for 10-20 minutes to warm up oil. Oil and contaminates will drain much better and you will have less of mess later.
- Drain with drain side tipping down to avoid oil running back under the pump and making a mess.
- Pour small amounts of clean oil/flushing fluid in inlet, then briefly run pump to flush out inside of casing.
- Separate the motor from pump housing before rest of disassembly.
## Minor Kit
> Recommended Vendor https://www.globaloring.com/
> Spec recomendations:
> - Viton (standard is FKM, other can work) or Nitrile
> - All P, G, S, V numbers in refference to JIS B2401 O-Ring Sizes. See https://www.globaloring.com/jisb-2401-metric-orings-2/ for more info.
> - Durometer 75 for orings.
| Description | Qnty | Notes |
| -------------------- | ---- | ----------------------------------------------------- |
| O-ring S-24 | 1 | |
| O-ring S-55 | 1 | |
| O-ring P-8 | 1 | |
| O-ring P-12 | 1 | |
| O-ring P-24 | 1 | |
| O-ring V-160 1 | 1 | |
| Oil Seal HTC-17-40-9 | 1 | I have used the more common 17-40-10 with no problem. |
| Oil Seal SC-17-30-7 | 1 | |
| Oil Seal SC-15-30-7 | 1 | |
| Teflon Tube O.D.1/8 | 1 | Used for gas ballast valve. Usually gets hard/clogged with use and sometimes breaks when you open the pump. Easy swap. |
## Major Kit
| Part | Qnty |
| --------------------- | ---- |
| Vane Spring φ2.4×24 | 8 |
| No. 1 Vane 62×15.5×t6 | 2 |
| No. 2 Vane 20×14×t6 | 2 |
| Oil Level Gauge | 1 |
| Bearing 6203 Open | 1 |
| Bearing 6002 Open | 1 |
| Sleeve SN1/8 | 2 |
| Middle Pin φ2×φ3.4×27 | 4 |
| Coupling | 1 |